Areas of Application
Flow generation
Water pumping
Aquatic habitats
Hatcheries
Koi ponds
RAS systems
Zoo enclosures
Technical Data
Hydraulic power
| Flow rate | 0 – 100 m³/h |
| Förderhöhe | 0 – 3 mWS |
| Operating pressure max. | 2.5 bar |
Motor & drive
| Drehzahl | 600 – 2600 min⁻¹ |
| Motor phases | 1-phasig |
| Insulation class | F |
Electrics
| Leistungsaufnahme P₁ max. | 0.09 – 1.34 kW |
| Leistungsabgabe P₂ max. | 0.05 – 1.15 kW |
| Rated current (230V) | 0.65 – 6 A |
Connections & piping
| Connection, inlet / suction side | 110 |
| Connection, discharge side | 110 |
| Recommended suction line diameter | 140 mm |
| Recommended discharge line diameter | 140 mm |
Materials
| Bundbuchse / Klebemuffe | PVC |
| Elastomere | NBR |
| Gleitringdichtung | SiC / NBR / SiC / Viton |
| Laufrad | PPE GF 30 / PP GF 30 |
| Pumpengehäuse | PP GF 30 |
| Dichtungsgehäuse | PP GF 30 |
| Flansch mit integrierter Laterne | PP GF 30 |
| Pumpenwelle | ABS |
Downloads
PDB BADU Novastar DE-EN-FR-NL-IT-ES 08-2023.pdfOperating Instructions
PDF
MZ BADU Novastar 03-2025.pdfDimensional DrawingsPDF
et-pl BADU Novastar 03-2024.pdfParts ListsPDF
et-l BADU Novastar 03-2024.pdfParts ListsPDF
KL BADU Novastar 02-2025.pdfCharacteristic CurvesPDF
KL BADU Novastar-S 02-2025.pdfCharacteristic CurvesPDF
BADU Novastar 2196000138.pdfDatasheetsPDF
BADU Novastar-S 2196000128.pdfDatasheetsPDF